製品情報

特徴

  • Three types are available for choice according to the installation method.
  • Most suitable for small inverters, servos, UPSs, power supplies, etc.
  • A 10-mm-φ fuse is compliant to the 60 A class.

定格

定格電圧・遮断容量
AC660V-10kA
DC660V(L/R2ms)-10kA
最小遮断電流
660V AC – 6 times the rated amperage
660V DC – 20 times the rated amperage
570V DC – 8 times the rated amperage
最大アーク電圧
1320V

660KH/KHK are not cUL approved.

  • Read “FOR SAFE USE” and “PROTECT FUSE USER’S GUIDE” at the back of this catalog before use.
  • A small fuse may generate a relatively large amount of heat, so a fuse with sufficient capacity is recommended for long, continuous use.
  • Fusing indication function is not provided.

660CF/KH/KHK

660CF

660KH

660KHK

UL規格認定定格

Rating 5 – 30 A

定格電圧・遮断容量
Same as the standard rating

※ 3 (660KH/KHK are not cUL approved.)

Rating 35 – 60 A

定格電圧・遮断容量
When applying the standard to UL standard approved items, use the fuse in the following rating.

AC660V-10kA
DC570V(L/R2ms)-10kA

※ 3 (660KH/KHK are not cUL approved.)

CCC規格認定定格

定格電圧・遮断容量
When applying the standard to CCC standard approved items, use the fuse in the following rating.

AC660V-10kA
DC450V(L/R10ms)-10kA

定格電圧

660V

定格電流

5~60A

筒サイズ

φ10×38

取り付けタイプ

Clipped/ Screwed/ Board soldered

RoHS指令

取得規格

cUL CCC

Specifications

Product Image

Dimensions

660CF <Fig1>

660CF <Fig1>

HK1038 (option)

HK1038 (option)

660KH <Fig2>

660KH <Fig2>

660KHK <Fig3>

660KHK <Fig3>

Fusing Characteristics

Product Image

Current-Limiting Characteristics

Product Image

Temperature Rise

660CF

660CF

660KH

660KH

660KHK

660KHK

Power Loss

660CF/660KH

660CF/660KH

660KHK

660KHK

Shutdown I²t Against Working AC Voltage

Product Image

Application to Direct-Current Circuit

Product Image